Fine Aggregate (Sand) Testing
Sieve analysis, fineness modulus, silt & clay content, specific gravity, water absorption, and bulking factor.
Service Overview & Scope
ATLES conducts thorough testing on natural river sand and manufactured sand (M-Sand) to evaluate suitability for concrete, plastering, and masonry work.
Engineering Purpose
To ensure fine aggregates are free from organic impurities, excessive silt, and meet grading zone specifications.
Key Civil Engineering Applications
Testing Methodology & Field Execution
Dry sieve analysis to classify sand into Zone I, II, III, or IV.
Sedimentation cylinder test for rapid silt content determination.
Specific gravity and 24-hour water absorption testing.
Bulking of sand experiment across varying moisture percentages.
Laboratory & Field Equipment
Engineering Significance
Prevents mortar cracking, reduces cement demand, and prevents concrete strength loss due to excessive fine silt.
Deliverable Reports & Certificates
- Grading Zone Classification & Fineness Modulus Report
- Silt & Organic Impurity Percentage Certificate
- Sand Bulking Curve Data Sheet
Inquire For Fine Aggregate (Sand) Testing
Request a quotation, schedule site testing, or sample pickup.